Avery Weigh-Tronix ZG310 Manuel de service Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
ZG310 Thermal Printer User Instructions 7
1.8.1 Alternative Power Supply Arrangements
The ZG310 is designed to be operated from a 9V to 36V voltage source that is capable
of supplying the primary power for the printer.
The electrical specification for the power supply input of the ZG310 printer is:
The average and peak current requirements can be adjusted by firmware control
codes. See the Service Manual for details.
The recommended power supply input is either a 12V or 24V vehicle battery, this allows
the printer to perform at its best. However, the printer will automatically accommodate
any DC input voltage in the range 9V to 36V. In addition, power supplies with lower
current capacities may be accommodated by varying the internal Power Save
parameter. See the Service Manual or contact the factory for more details.
The recommended power supply input is either a 12V or 24V vehicle battery, this allows
the printer to perform at its best. However, the printer will automatically accommodate
any DC input voltage in the range 9V to 36V.
1.9 Printer Firmware Revisions
The manufacturer reserves the right to modify and improve the firmware in its printer
products at any time. Every effort is made to ensure backward compatibility, however,
no guarantee in this respect is given or implied.
The ZG310 includes a flash-reprogrammable microcontroller. This allows firmware
upgrades under customer control (including customized fonts, which may be created
using the Font Editor Utility). Refer to the factory for more information in this feature, if
required.
1.10 Copyright Notice and Disclaimer
Copyright subsists in the manufacturer's intellectual property, including controller
firmware (embedded software) and circuit diagrams, pin connection lists and
application data. No warranty in respect of patent rights of the manufacturer or of third
parties is given. Unauthorized reproduction or amendment of controller firmware may
result in prosecution.
Fujitsu is a registered mark of its owner Fujitsu Limited. References to this or other
owners' marks in this document are for illustrative purposes only.
The manufacturer does not assume responsibility for interchangeable functionality of
other parties' command sets.
Input Voltage Range: +9V to +36V internal over voltage at 37V and reversal protection
Supply Current Requirement: 50mA Printer in Idle Mode
( typical @24V in ) 1A average Printer Printing
4A peak Printer Printing