Avery Weigh-Tronix ZG310 Manuel de service Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
16 ZG310 Thermal Printer User Instructions
5.4 Graphics Printing and Other Programming Modes
Various dot-addressable graphics modes are supported, at up to 384 dots per line.
Refer to the Service Manual for full details of this and other advanced programming
modes.
5.5 Interface Details
5.5.1 RS-232 Serial Interface
The ZG310 printer has an industry standard RS-232 interface. The default parameters
are 9600 baud, 8 data bits, 1 stop bit and no parity. Other baud rates can be
programmed by control codes, or by using a setup utility available from the factory.
Serial data is expected in standard RS-232 format with -12V meaning mark or 1 and
+12V a logical 0, with reference to the common ground. The serial data output line,
TxD, transmits XON/XOFF and status information to the host at the same baud rate
and in the same format as the serial data input.
The hardware busy line is true (nominal -12V) when busy. Both serial output lines will
relax to approximately 0V when the ZG310 is off, and the user must allow a short period
after switching on before relying on the values of these signals.
Some host equipment uses a constant space condition (+12V) to indicate a reset
condition or wait state. Some battery powered host equipment present the same output
signal when they go to sleep. The ZG310 can be set to ignore this condition as detailed
in the Service Manual, but even then this type of host behavior may result in one or
more spurious characters being received and printed.